电解水制氢厂站经济性分析
|
徐进, 丁显, 宫永立, 何广利, 胡婷
|
Economic analysis of hydrogen production plant with water electrolysis
|
Jin XU, Xian DING, Yongli GONG, Guangli HE, Ting HU
|
|
表12 无大修和1次大修情况下的电解电耗计算 (kWh/Nm3H2)
|
Table 12 Calculation of electrolysis power consumption under the condition of no overhaul and one overhaul
|
|
投入运行年份 | 无大修 | | 1次大修 |
---|
电解电耗 | 压缩电耗 | 综合电耗 | | 电解电耗 | 压缩电耗 | 综合电耗 |
---|
1 | 5.00 | 0.13 | 5.13 | | 5.00 | 0.13 | 5.13 | 2 | 5.04 | 0.13 | 5.17 | 5.04 | 0.13 | 5.17 | 3 | 5.08 | 0.13 | 5.21 | 5.08 | 0.13 | 5.21 | 4 | 5.12 | 0.13 | 5.25 | 5.12 | 0.13 | 5.25 | 5 | 5.16 | 0.13 | 5.29 | 5.16 | 0.13 | 5.29 | 6 | 5.20 | 0.13 | 5.33 | 5.20 | 0.13 | 5.33 | 7 | 5.24 | 0.13 | 5.37 | 5.24 | 0.13 | 5.37 | 8 | 5.28 | 0.13 | 5.41 | 5.28 | 0.13 | 5.41 | 9 | 5.32 | 0.13 | 5.45 | 5.32 | 0.13 | 5.45 | 10 | 5.36 | 0.13 | 5.49 | 5.36 | 0.13 | 5.49 | 11 | 5.40 | 0.13 | 5.53 | 5.40 | 0.13 | 5.53 | 12 | 5.44 | 0.13 | 5.57 | 5.44 | 0.13 | 5.57 | 13 | 5.48 | 0.13 | 5.61 | 5.48 | 0.13 | 5.61 | 14 | 5.52 | 0.13 | 5.65 | 5.00 | 0.13 | 5.13 | 15 | 5.56 | 0.13 | 5.69 | 5.04 | 0.13 | 5.17 | 16 | 5.60 | 0.13 | 5.73 | 5.08 | 0.13 | 5.21 | 17 | 5.64 | 0.13 | 5.77 | 5.12 | 0.13 | 5.25 | 18 | 5.68 | 0.13 | 5.81 | 5.16 | 0.13 | 529 | 19 | 5.72 | 0.13 | 5.85 | 5.20 | 0.13 | 5.33 | 20 | 5.76 | 0.13 | 5.89 | 5.24 | 0.13 | 5.37 | 21 | 5.80 | 0.13 | 5.93 | 5.28 | 0.13 | 5.41 | 22 | 5.84 | 0.13 | 5.97 | 5.32 | 0.13 | 5.45 | 23 | 5.88 | 0.13 | 6.01 | 5.36 | 0.13 | 5.49 | 24 | 5.92 | 0.13 | 6.05 | 5.40 | 0.13 | 5.53 | 25 | 5.96 | 0.13 | 6.09 | 5.44 | 0.13 | 5.57 | 平均综合电耗 | | | 5.61 | | | 5.36 |
|
|
|