储能科学与技术 ›› 2022, Vol. 11 ›› Issue (8): 2497-2504.doi: 10.19799/j.cnki.2095-4239.2022.0252

• 电化学储能安全专刊 • 上一篇    下一篇

全氟己酮气体灭火系统在磷酸铁锂电池储能预制舱的应用

蔡兴初1(), 朱一鸣1, 姜可尚2, 席旭峰1, 张艺超2, 林惟实1   

  1. 1.中国能源建设集团江苏省电力设计院有限公司,江苏 南京 211102
    2.安徽中科久安新能源 有限公司,安徽 合肥 230000
  • 收稿日期:2022-05-10 修回日期:2022-06-10 出版日期:2022-08-05 发布日期:2022-08-03
  • 通讯作者: 蔡兴初 E-mail:caixingchu@ jspdi.com.cn
  • 作者简介:蔡兴初(1978—),男,硕士,教授级高级工程师,研究方向为电力工程供排水和消防设计,E-mail:caixingchu@ jspdi.com.cn

Application on perfluoro-2-methyl-3-pentanone in lithium battery premade energy storage cabin

Xingchu CAI1(), Yiming ZHU1, Keshang JIANG2, Xufeng XI1, Yicao ZHANG2, Weishi LIN1   

  1. 1.China Energy Engineering Group Jiangsu Power Design Institute CO. , Ltd. , Nanjing 211102, Jiangsu, China
    2.Anhui CAS-Jiuan New Energy Technology CO. , Ltd. , Hefei 230000, Anhui, China
  • Received:2022-05-10 Revised:2022-06-10 Online:2022-08-05 Published:2022-08-03
  • Contact: Xingchu CAI E-mail:caixingchu@ jspdi.com.cn

摘要:

“双碳”目标下,需要建设大量与“风”“光”等新能源配套的磷酸铁锂电池储能电站,但磷酸铁锂电池具有较大火灾危险性,其灭火措施研究尚不完善。全氟己酮灭火剂是一种新型哈龙和氢氟烃类灭火剂的优良替代品,对其是否适用于扑灭储能锂电池火灾并抑制其热失控存有争议。基于全氟己酮应用于磷酸铁锂电池火灾的既往研究成果,优化了全氟己酮气体应用于磷酸铁锂电池储能电池舱的灭火方式,采用“局部应用”与“全淹没”灭火方式相结合,通过模型试验验证了灭火效果并得出了相关设计参数,以工程案例详细论述了全氟己酮气体灭火系统在储能电池舱的应用方案。

关键词: 磷酸铁锂电池, 全氟己酮, 储能预制舱, 消防

Abstract:

In the context of carbon peak and carbon neutralization, renewable energy sources, such as wind and light, are gradually becoming the dominant energy sources. Energy storage facilities, primarily lithium iron phosphate batteries in prefabricated energy storage cabins, are required. However, lithium iron phosphate batteries with a high risk of thermal runaway are likely to cause great fire hazards. Although perfluoro-2-methyl-3-pentanone is an excellent substitute for halons and HFCs fire extinguishing agents, its suitability for extinguishing energy storage lithium battery fires and suppressing thermal runaway is debatable. A perfluoro-2-methyl-3-pentanone fire extinguishing method combining "local application" and "total submersion" is proposed based on some experimental results of perfluoro-2-methyl-3-pentanone applied to lithium iron phosphate battery fires. The fire-extinguishing mechanism is verified by model tests, and the relevant design parameters are obtained. An engineering case is used to discuss the application scheme of a perfluoro-2-methyl-3-pentanone fire-extinguishing system in a prefabricated energy storage cabin.

Key words: lithium iron phosphate battery, perfluoro-2-methyl-3-pentanone, prefabricated cabin, fire protection