Performance of precooled CAES system using ORC-VCR to recover compression heat

Liugan ZHANG1,2(), Yingchi ZHOU3, Wenbing SUN3, Kai YE2, Longxiang CHEN2,4()   

  1. 1.College of Mechanical and Electrical Engineering, Fujian Agriculture and Forestry University, Fuzhou 350002, Fujian, China
    2.Quanzhou Institute of Equipment Manufacturing, Haixi Institutes, Chinese Academy of Sciences, Quanzhou 362200, Fujian, China
    3.Fujian Hongshan thermal power Co. , LTD, Quanzhou 362700, Fujian, China
    4.University of Chinese Academy of Sciences, Beijing 100049, China
  • Received:2023-08-24 Revised:2023-08-31 Online:2024-02-28 Published:2024-03-01
  • Contact: Longxiang CHEN E-mail:zhanglg0921@163.com;chenlx@fjirsm.ac.cn

摘要:

常规非绝热压缩空气储能(D-CAES)系统的储能过程通常采用四级以上的压缩机组以减少空气压缩功的消耗,导致产生大量的低品位压缩热直接排放到环境中,能源浪费严重。针对这一问题,本工作提出了一种采用有机朗肯循环-蒸汽压缩制冷(ORC-VCR)回收压缩热的预冷式CAES系统(ORC-VCR-CAES),通过回收空气压缩阶段压缩机产生的压缩热来对压缩机入口空气进行预冷,可以进一步降低空气压缩功的消耗,提高系统的循环效率。对ORC-VCR-CAES耦合系统进行了热力学分析和经济性分析。结果表明,不同ORC-VCR循环工质对系统性能的影响较大,采用R152a作为循环工质的ORC-VCR-CAES系统综合性能最佳。其系统循环效率可达64.15%,比常规D-CAES系统提高了5.94%;在考虑外部废热能量输入时,ORC-VCR-CAES系统?效率为51.90%,比常规D-CAES系统提高了4.81%。通过压缩热的回收有效减少了冷却器的?损失,但压缩机组的?损失仍然较大,是系统进一步优化的关键部件;经济性分析表明,当峰谷电价为1.26元和0.30元时,ORC-VCR-CAES系统的项目净现值相比于常规D-CAES系统可增加12.48%,且峰谷电价差越小,ORC-VCR-CAES相比于常规D-CAES系统的项目净现值增加百分比越高。

关键词: 压缩空气储能, 有机朗肯循环, 蒸汽压缩制冷, 热力学分析, 经济性分析

Abstract:

The energy storage process in a conventional diabatic compressed air energy storage (D-CAES) system usually uses more than four compressor units to reduce the consumption of air compression work. However, this leads to a substantial discharge of low-grade compression heat into the environment and serious energy waste. To solve this problem, this study proposes a precooled CAES system that uses organic Rankine cycle-steam compression refrigeration (ORC-VCR) for compression heat recovery (ORC-VCR-CAES). In the proposed system, the compressor inlet air is precooled by recovering the compression heat generated during the air compression stage. This approach further reduces the consumption of air compression work and improves the round-trip efficiency of the system. The thermodynamic and economic analysis of the ORC-VCR-CAES coupling system are also performed. Results show that the choice of ORC-VCR cycle working medium considerably influences system performance. The ORC-VCR-CAES system using R152a as a cycle working medium exhibits the best performance, achieving a system cycle efficiency of 64.15%, which is 5.94% higher than that of the conventional D-CAES system. Moreover, considering external waste heat energy input, the ORC-VCR-CAES system attains an energy efficiency of 51.90%, which is 4.81% higher than that of the conventional D-CAES system. Although the energy loss in coolers is effectively reduced through the recovery of compression heat, the energy loss from compressor units is still large, which is a key equipment for further system optimization. Economic analysis shows that with peak and valley electricity prices at 1.26 and 0.30 CNY, the net present value of the ORC-VCR-CAES system increases by 9.64% compared to the conventional D-CAES system. Compared with the conventional D-CAES system, the percentage increase in the net present value of the ORC-VCR-CAES system is higher when the peak and valley electricity price difference is smaller.

Key words: compressed air energy storage, organic Rankine cycle, vapor compression refrigeration, thermodynamic analysis, economic analysis